Tìm kiếm nâng cao
Sản Phẩm
Video clip
Hỗ trợ trực tuyến
Hỗ trợ trực tuyến

GỌI ĐẶT HÀNG: 1900 633 603

HỖ TRỢ KỸ THUẬT: 028-7300 3603


-------------------------------------------------

 HOT NEWS!!!

*** Smarttech tham dự Hội Nghị Thượng Đỉnh về Chuỗi Cung Ứng Lạnh Thế Giới (World Cold Chain Summit 2018) 

 -------------------------------------------------

GPP (Thông tư 02/2018/TT-BYT-Quy định về Thực hành tốt cơ sở bán lẻ thuốc)

 

 

 

 

 

 
Thông tin
Liên kết website

THIẾT BỊ GHI NHIỆT ĐỘ VÀ HIỂN THỊ CẢNH BÁO LOGTAG® TICT

Giá: Yêu cầu báo giá

Hàng có sẵn:
Model: TICT
Xuất sứ:
Chi tiết sản phẩm:

The LogTag® TICT is a low cost disposable electronic temperature indicator for use in monitoring temperature & time statistics in transport applications of up to 45
days duration.

The LogTag TICT can monitor and record statistics against four factory pre-set temperature limits for up to 45 days, displaying OK if environmental conditions
remain within limits. If temperatures exceed two high temperature alarm limits or go below two low temperature alarm limits, the LCD shows a REJECT alert, indicating the goods require further checking.

 

 

The LogTag TICT is factory pre-configured for one of a range of monitoring profiles. Special profiles are available on request, subject to conditions.

Statistical data can be downloaded from the TICT using the LogTag Indicator interface cradle and freely available LogTag Analyzer operating software if required.

The TICT offers an accurate and cost effective solution for monitoring the cold chain in “last mile” distribution and other applications where full data logging capability is not required.

Monitoring Display
LOAD OK
Monitoring Display
LOAD REJECT


Highlights

Factory pre-configured to monitor a range of products including standard vaccines
Standard 60 minute start delay
Clear indication of temperature history/alarm status at all times.
Monitors for up to 45days
Push button Start and Stop.
Data can be downloaded via an interface cradle and LogTag Analyzer if required.
Robust and Accurate. Data collected is secure and cannot be manipulated.
Fits easily into packages and can be mailed via letter rate.
   
   
Downloads

Product Brochure

 
Product Specification
 

Profile Configuration

 

 

Specifications
Model#
 
TICT
Operating temperature range
 
-25°C to +60°C (-13°F to +140°F)
Ambient humidity range during transport and use
 
0% to 95%RH
Rated Temperature reading accuracy
 
±0.5°C (±1.5°F) or better for -10°C to +25°C (+14°F to +77°F).
±1.0°C (±2.0°F) or better for range of -25°C to -10°C (-13°F to +14°F).
±1.0°C (±2.0°F) or better for range of +25°C to +60°C (+77°F to +140°F).
Sensor reaction time (T90)
 
T90 less than 7 minutes by method detailed in EN12830:1999.
Resolution
 
0.1°C from -25°C ~ +60°C (-13°F ~ +140°F)
Capacity
 
Minimum & maximum temperature for each of the 45 days. 1st activation of each alarm for each day including trigger time and duration of each excursion.
Sampling interval
 
Factory set to 5 minute interval
Memory type
 
Non volatile
Recordings
 
45 day statistics, temperature/time excursions and alarm trigger time and duration for each day.
Start Delay
 
Factory pre-set between 1 and 255 minutes; 60 minute delay for profile 0001
Environmental
 
IEC 60529: IP64
Power source
 
3V Lithium-Manganese Dioxide, non replaceable
Battery life
 
Minimum storage life of 18 months before ‘start’. Monitoring period: 45 days. Minimum accessibility (display) period of 6 months after ‘stop’
Size
 
71.5mm (W) x 33.0mm (H) x 8.6mm (T)
Weight
 
19 grams
Case Material
 
Polycarbonate
Reader interface
 
LogTag TIC/TICT reader interface only
Calibration
 
Certificate of Traceability and Calibration to ISO/IEC17025 available on request.
Warranty

 

One year replaceable warranty against defects in materials and workmanship from the date of purchase. Excludes misuse or abuse of the product or as a result of unauthorized alteration or repairs.
Note: Resolution & Accuracy are rated values - actual product performance may be substantially better than figures stated.

 

Standards compliance
EMC Compliance
 
EC EMC directives (EN 61000-6-1:2005 & EN 61000-6-3:2006) Including electrostatic discharge as prescribed in EN 61000-4-2. Complies with FCC Part 15 Subparts A and B.
 
Manufactured to meet the European RoHS Directive
The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants.

 

 

Accessories

 


INTERFACE CRADLE

The LogTag® TIC20/TICT reader interface is a special interface for reading the temperature indicator products and allows download of stored statistical and alarm trigger data for viewing & processing with LogTag Analyzer.

Details coming soon.

 

 